Product Description
GE THQL2150GFT - 50A Double Pole 120/240V Circuit Breaker with Self Test
DESCRIPTION
Q-Line® circuit breakers are 1 in wide per pole, compact, thermal magnetic devices designed for residential and commercial applications. the QL breakers are plug-in versions of the Q-Line® used for connection to loadcenters and lighting panels. all Q-Line® circuit breakers feature quick-make quick-break mechanisms, common trip bars and easy to spot trip indication to ensure safety and reliability. Q-Line® breakers are available in 1, 2 and 3-pole versions, can be ordered with auxiliary contact and shunt trip accessories and can be ordered for use in HID applications.
Q line circuit breakers are one-inch wide per pole, compact, thermal-magnetic devices designed for residential and commercial applications. The QL breakers are plug-in versions of the Q Line used for connection to load centers and lighting panels. All Q Line circuit breakers feature Quick-make / Quick-break mechanisms, common trip bars, and easy to spot trip indication to ensure safety and reliability. Q Line breakers are available in 1, 2, and 3 pole versions, can be ordered with auxiliary contact and shunt trip accessories, and can be ordered for use in HID applications. 0GFT Amps 50 A
SPECIFICATIONS
Amperage Rating | : | 50 A |
Dimensions | : | 3-9/32 in H x 2 in W x 2-3/8 in D |
Frame | : | THQL |
Interrupt Rating | : | 10 kA |
Mounting Type | : | Plug-In |
Number of Poles | : | 2 |
Phase | : | 1 |
Trip Range | : | 5 mA |
Trip Type | : | Non-Interchangeable/LIG |
Type | : | Model 3 Self-Test |
Voltage Rating | : | 120/240 VAC |
Wire Size | : | 14 to 8 AWG Cu, 12 to 8 AWG Al |
FEATURES
- The national electrical code requires GFCI protection of receptacles located outdoors, in bathrooms, garages and spa areas
- This applies not only to new construction, but also to existing homes
- When an electrical outlet is replaced in a location that requires ground fault protection, the new outlet must be GFCI protected, according to the NEC®
- The GFCI circuit interrupter provides protection against overloads, short circuits and ground faults
- It detects very low levels of electrical current leakage (ground faults) and acts quickly to shut off power, preventing serious shock
- Push button test validates the ground fault detection capability of the breaker
- Class A 5 mA ground fault circuit interrupter
- Quick-make, quick-break mechanism
- Suitable for reverse feed
- Standard continuous current rated
- 60 deg C/75 deg F conductor rating
- Box type terminals
- Multi-pole circuit breakers incorporate internal common trip